The appliances put together are live.
Obey the electrical safety rules.
The Rated voltage of the appliances put together must agree.
Adjust the plug and socket connections together correctly.
Install correctly to give shock protection.
Loose and incorrect plug and socket connections can make the terminal become too hot.
A qualified electrician must install the connections in the clamps correctly.
The appliance must have the electrical installation which lets you disconnect the appliance
from the mains at all poles with a contact opening width of minimum 3 mm.
You must have correct devices to isolate: line protecting cut-outs, fuses (screw type fuses
removed from the holder), earth leakage trips and contactors.
Assembly
min.
50mm
min.
50mm
min.
500mm
min.
5mm
=
=
490
+1
mm
560
+1
mm
600mm
R 5mm
min.
38 mm
min.
5 mm