ARE I2 / RS 232 – Installation Guide
AEG
Identifikationssysteme GmbH
Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
Wait for the answer
Analyse the received answer: 3 characters plus <CR>.
<ACK> <CR> Writing process was successful
<NAK> <CR> Writing process was not successful.
<NOT> <CR> The response of the transponder was not readable.
The result of the writing process may also seen at the LED’s.
LED L2 lit, if there was a successful write
LED L3 lit, if there was no successful write.
Example
WD <SP> 20 <SP> < 0 1 2 7 A C D F > <CR> Write to block 20
Allowed Values (block numbers of the transponder IC):
ALGO 9 (1kBit Memory) 3 .... 31
ALGO 6 (2kBit Memory) 16 ... 63